Flow Cells: PDMS Casting and System Integration
Brochure
- Applications
In order to immobilize molecules or cells in microfluidic channels, the flow-through system should be designed such that it can be closed and opened again. It would be also ideal if one and the same fluidic system could be utilized for different analytical (e.g., electrochemical or optical) methods by very simple modification and also allow efficient cleaning.
For this purpose, provided are flow-through chambers with removable coverslips for the microscope. These flow cells are mounted in seconds and can be applied in cell imaging or single molecule fluorescence. If needed, electrical signals can be transferrd or optical fibers mounted.
Layout and assembly of the microsystem can be modified in a wide range. So in addition to PDMS, other materials can be used and microvalves and microelectrodes can be integrated. Due to the easy and modular setup, even the most complicated methods in screening and nanotechnology can be realized.
Our approach is to provide modular solutions for microstructuring that are complementary to the microfluidic applications that we work with. Provided are numerous approaches towards developing 3-dimensional surface topographies. These systems are developed for precision liquid handling for microscopic imaging and can be integrated with the Nano-Plotter platform.
Catalog
Mechanical Components
| Code |
Description |
| A040-018 |
MicCell Support, standard, aluminum |
| A040-019 |
MicCell Support, with printed circuit board |
| A040-109 |
MicCell Lid, 22x22 mm |
| A040-110 |
MicCell Lid, 22x50 mm |
MicCell Fluid Processor
| Code |
Description |
| A050-005 |
MicCell Fluid Processor, 4-channel version |
| A050-007 |
MicCell Fluid Processor, standard version |
| A050-008 |
MicCell Twin Fluid Processor |
| A110-015 |
Smart Valve Upgrade, 4-port |
MicCell Casting Station
| Code |
Description |
| A040-030 |
Silicon Master Chip, structure height 2 - 50 µm |
| A040-031 |
Silicon Master Chip, structure height 50 - 150 µm |
| A040-033 |
MicCell PDMS Casting Station |
| A040-091 |
MicCell Channel Spacer |
MicCell Accessories
| Code |
Description |
| A040-080 |
Hydrogel Microvalve PV5, PEEK housing |
| A040-081 |
Hydrogel Microvalve PV6, PEEK housing |
| A040-100 |
Hydrogel Microinjector PV6, PEEK housing |
| A040-101 |
Hydrogel Microvalve PV6, naked chip |
| A040-084 |
MicCell Sample Carrier |
MicCell Consumables
| Code |
Description |
| A040-105 |
MicCell PDMS Channel Plate 22x22 mm, recycled |
| A040-106 |
MicCell PDMS Channel plate 22x22 mm, new |
| A040-107 |
MicCell PDMS Channel Plate for Sample Carrier |
| A040-108 |
MicCell PDMS Channel Plate 22x50 mm, new |
| A040-111 |
MicCell PDMS Channel Plate 22x50 mm, recycled |
| A040-112 |
MicCell PDMS CP 22x22 mm with 4 electrodes |
| A040-026 |
MicCell Glass Slide, with SiR channel |
| A040-027 |
Coverslip, 150 µm, with Pt electrodes and SiR channel |
| A040-044 |
Coverslip, 150 µm thick, glass, customized size |
| A040-102 |
Coverslip, 150 µm thick, with platinum electrodes |
| A040-103 |
Coverslip, 150 µm thick, with ITO electrodes |
| A040-104 |
Coverslip, 150 µm, with SiO -passivated Pt electrodes |
| A660-300 |
MicCell PDMS Syringe, 5 ml |
| A660-301 |
MicCell PDMS Syringe, 1 ml |
| A660-302 |
MicCell Injection Needles |
| A660-303 |
MicCell PDMS Mixing Glass |
MicCell Software
| Code |
Description |
| A070-089 |
MicCell Software, standard version |